16 Channel Analog Input Module

Item No:
S830-12C04CV04G04GIND
16 Channels Analog Input Module
No. of Analog Inputs
16 Channels
Type Of Analog Inputs
12 Nos 0/4-20 mA
4 Nos. mA/Voltage Selectable
Hardware Functional Status
From July 22
Firmware Version
1.00.001
Firmware Update Possible
Yes
Engineering Software
CODESYS V3.5 SP19 and above
Mounting
Base Unit TBUS-PPPPPPPP
No. of Analog Inputs
16 Channels
Type Of Analog Inputs
12 Nos 0/4-20 mA
4 Nos. mA/Voltage Selectable
4 Nos. mA/Voltage Selectable
Hardware Functional Status
From July 22
Firmware Version
1.00.001
Firmware Update Possible
Yes
Engineering Software
CODESYS V3.5 SP19 and above
Mounting
Base Unit TBUS-PPPPPPPP
Galvanic Isolation
Yes
Galvanic Isolation Groups
04 Group
Channel In One Group
04 Channel/Group
Input Short-Circuit Protection
Yes For Each Channel (For mA Channel only)
Input Over-Current Protection
Yes (40 mA)
Galvanic Isolation
Yes
Galvanic Isolation Groups
04 Group
Channel In One Group
04 Channel/Group
Input Short-Circuit Protection
Yes For Each Channel (For mA Channel only)
Input Over-Current Protection
Yes (40 mA)
Power Supply From
Top Side De-Coded Plug-In Screw Terminal
Normal Supply Voltage
24 V DC
Low Supply Voltage
21.6 V DC
High Sypply Voltage
26.5
Reverse Polarity Protection
Yes
Input Current
0.5 A
Input Current Per Channel Permissible
25 mA
Transmitter Power
Yes
Power Loss
Less than 1 W
Power Supply From
Top Side De-Coded Plug-In Screw Terminal
Normal Supply Voltage
24 V DC
Low Supply Voltage
21.6 V DC
High Sypply Voltage
26.5
Reverse Polarity Protection
Yes
Input Current
0.5 A
Input Current Per Channel Permissible
25 mA
Transmitter Power
Yes
Power Loss
Less than 1 W
Input Range
0-20 mA
Input Range
4-20 mA
Input Range
0-10 V
Input Range
1-10 V
Input Range
0-10 mA
Measuring Range
Scalable
Input Resistance
120 Ω in mA selection
Input Impedance
10k ohm in Voltage Selection
Input Range
0-20 mA
Input Range
4-20 mA
Input Range
0-10 V
Input Range
1-10 V
Input Range
0-10 mA
Measuring Range
Scalable
Input Resistance
120 Ω in mA selection
Input Impedance
10k ohm in Voltage Selection
Perameterization in Run
Yes
Calibration in Run
Yes
Perameterization in Run
Yes
Calibration in Run
Yes
Automatic Encoding
No
Mechanical Coding Element
Yes
Automatic Encoding
No
Mechanical Coding Element
Yes
Analog Input Measuring Principle
Sigma Delta (Integrating)
Analog Input Measuring Principle
Sigma Delta (Integrating)
Resolution (with over-range)
12 Bit
Conversion Time Per Chennal
100 ms
Resolution (with over-range)
12 Bit
Conversion Time Per Chennal
100 ms
Linearity Error
0.1% (Input Range)
Operational Error
0.5% (Input Range)
Basic Error
0.3% (Input Range)
Linearity Error
0.1% (Input Range)
Operational Error
0.5% (Input Range)
Basic Error
0.3% (Input Range)
Series Mode Interference
Min 70 dB
Common Mode Voltage
Max 10 V
Common Mode Interference
90 dB
Series Mode Interference
Min 70 dB
Common Mode Voltage
Max 10 V
Common Mode Interference
90 dB
Dignotics Alarm
Yes
Limit Alarm
Yes
Dignotics Alarm
Yes
Limit Alarm
Yes
Function Of Diagnostic
Available
Module Fuse Blown Indication
Yes
Function Of Diagnostic
Available
Module Fuse Blown Indication
Yes
Wire-Break
Yes (4-20 mA)
Short Circuit
Yes (For mA Channel Only)
Channel Diagnostics
Yes
Wire-Break
Yes (4-20 mA)
Short Circuit
Yes (For mA Channel Only)
Channel Diagnostics
Yes
Power Indication
Yes
Channel Status
No
Channel Diagnostics (Wire-Break Joint)
No
Module Diagnostics (Back-Plane Comm)
Yes
Power Indication
Yes
Channel Status
No
Channel Diagnostics (Wire-Break Joint)
No
Module Diagnostics (Back-Plane Comm)
Yes
Seperation Between Channel
Yes (Group Isolation) In Group of 4 channel
Seperation Between Backplane
Yes
Seperation Between Channel and System Power Supply
Yes
Insulation Tested With
500 V DC
Seperation Between Channel
Yes (Group Isolation) In Group of 4 channel
Seperation Between Backplane
Yes
Seperation Between Channel and System Power Supply
Yes
Insulation Tested With
500 V DC
Horizontal Installation
0°C
Horizontal Installation
60°C
Vertical Installation
0°C
Vertical Installation
60°C
Horizontal Installation
0°C
Horizontal Installation
60°C
Vertical Installation
0°C
Vertical Installation
60°C
Field Connection
37-Pin D-Sub Female Connector
Power Connection
5 Pin Phoenix Plug-In Screw Connector (De-Coded)
Field Connection
37-Pin D-Sub Female Connector
Power Connection
5 Pin Phoenix Plug-In Screw Connector (De-Coded)
Cable Length Max.
500 m, 1.0 mm² shielded cable
Address Space Per Module
32 Bytes
Dimensions (W x H x D)
25 x 122 x 115 mm
Weight
160g Approx
Cable Length Max.
500 m, 1.0 mm² shielded cable
Address Space Per Module
32 Bytes
Dimensions (W x H x D)
25 x 122 x 115 mm
Weight
160g Approx
The analog input module is an essential component of our PLC system, designed to seamlessly integrate analog signals into automation processes. It interfaces with various external devices such as sensors, transmitters, variable frequency drives (VFDs), and transducers allowing precise monitoring and control of critical operations within the plant. This model offers 16 channels and incorporates galvanic isolation across four groups of four channels each, ensuring reliable performance and enhanced safety across all connected systems.